Column shoe Type I - PI
This foot pillars are galvanized and are suitable for mounting wooden pilots to basics.
Product Details
Features
Material
Steel quality:
S 235 JR according to DIN EN 10025
Corrosion protection:
Galvanizing layer thickness of about 55 microns in accordance with DIN EN 1461
Benefits
• footing post PI are used directly in concrete and absorb forces in compression, tensile and horizontal forces.
• These barely visible beads were developed as an alternative or a supplement to the beads PPD.
• allow secure and easy to install.
• Constructive wood protection is very good.
• Feet are made in one size: mainly for fixing the carrier with dimensions of 100 × 100, 120 × 120 and 140 × 140th
Application
Applicatons
Wood, wood products, concrete
Scope
• Especially designed for use in lightweight structures, such as garages covers, pergolas, terraces and the like.
Technical Data
Capacities
References | Number of Fasteners | Characteristic capacities - Timber C24 [kN] | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
On post | R1.k | R2.k | R3.k | R4.k | |||||||||||||
Qty | Type | Width of post [mm] | Width of post [mm] | Width of post [mm] | |||||||||||||
60 | 80 | 100 | 120 | 60 | 80 | 100 | 120 | 60 | 80 | 100 | 120 | 140 | 160 | ||||
PIG | 4 | STD8xL | 54.5/kmod | 13.8 | 16 | 18.7 | 20.7 | min (9.4 ; 7.9/kmod) | min (10.9 ; 7.9/kmod) | min (12.7 ; 7.9/kmod) | 7.9/kmod | 3.1 | 4.1 | min (5.9 ; 5.3/kmod) | min (7.9 ; 5.4/kmod) | min (9.4 ; 5.7/kmod) | 6.3/kmod |
Load combination:
Product characteristic capacities - Simplified values
References | Number of Fasteners | Simplified product capacities - Timber to concrete | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
On post | R1,k* | R2,k* | R3,k* | R4,k* | |||||||||||||
Qty | Type | Width of post [mm] | Width of post [mm] | Width of post [mm] | |||||||||||||
60 | 80 | 100 | 120 | 60 | 80 | 100 | 120 | 60 | 80 | 100 | 120 | 140 | 160 | ||||
PIG | 4 | STD8xL | 77.8 | 13.8 | 16 | 18.7 | 20.7 | 9.4 | 10.9 | 11.3 | 11.3 | 3.1 | 4.1 | 5.9 | 7.9 | 8.1 | 9 |
*The published characteristic capacity is based on medium term load duration and service class 3 according to EC5 (EN 1995) (kmod = 0.7). For other load duration and service class, please refer to the ETA to get more accurate capacities.
**Refer to the Simpson Strong-Tie anchor product range for suitable anchors. Typical anchor solutions depend on the concrete type, spacing and edge distances.
Installation
Installation
Fasteners
• These shoes are concreted.
• The distance between the pressure plate to the concrete should not exceed 50 mm.
• Port on wood is done with dowels ∅8
Installation
Upper part :
- Make a vertical notch in the column (width depending on the thickness of the vertical plate),
- Identify the position of the dowels (or bolts) on the sides of the column,
- Drill transversely the column to insert the dowels (drilling diameter depending on the diameter of the dowels),
- Position the postbase and insert the dowels.
Lower part :
- Fix the postbase to the column,
- Drill the support vertically, to the recommended diameter and depth,
- Put the post in place and finalize the fixing to the ground by means of sealing,
- The postbase can also be embedded in the concrete at the moment when the latter is poured.