Reinforced Angle Bracket
Reinforced angle brackets are suitable for structural applications in framing and wood-frame houses.
Product Details
Features
Material
- Galvanized steel S250GD + Z275 according to NF EN 10346.
Application
Header member
- Supporting member: solid wood, glued-laminated wood, concrete, steel, etc.
- Supported member: solid wood, composite lumber, glued-laminated wood, triangular trusses, profiles, etc.
For Use With
- Fastening of small trusses.
- Cladding plates, cladding uprights.
- Rafter anchors, cantilevers, headers, etc.
Technical Data
Product Dimensions
References | Product Dimensions [mm] | Joist | Holes flange B | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
A | B | C | t | Ø5 | Ø13 | Ø11x22 | Ø5 | Ø11 | Ø13 | Ø11x22 | Ø12x20 | |
E5/1.5 | 76.5 | 49.5 | 65 | 1.5 | 7 | - | 1 | 6 | - | - | 1 | - |
E5/1.5/11.22/11 | 76.5 | 49.5 | 65 | 1.5 | 7 | - | 1 | 6 | 1 | - | - | - |
E5/2 | 77 | 50 | 65 | 2 | 7 | - | 1 | 6 | - | - | 1 | - |
E4/2.5 | 102.5 | 62.5 | 75 | 2.5 | 7 | 1 | - | 6 | - | - | - | 1 |
E6/2 | 122 | 62 | 75 | 2 | 11 | 1 | - | 6 | - | - | - | 1 |
E6/2.5 | 122.5 | 62.5 | 75 | 2.5 | 11 | 1 | - | 6 | - | - | - | 1 |
E7/2.5 | 142.5 | 62.5 | 75 | 2.5 | 12 | 1 | - | 6 | - | - | - | 1 |
E8/2.5 | 162.5 | 62.5 | 75 | 2.5 | 12 | 2 | - | 6 | - | - | - | 1 |
E14/2 | 82 | 52 | 75 | 2 | 8 | 1 | - | 4 | - | 1 | - | - |
E17/2 | 152 | 52 | 75 | 2 | 15 | 2 | - | 4 | - | 1 | - | - |
E18/2.5 | 152.5 | 52.5 | 75 | 2.5 | 15 | 2 | - | 4 | - | 1 | - | - |
E19/3 | 153 | 53 | 75 | 3 | 15 | 2 | - | 4 | - | 1 | - | - |
E5/2C50 | 75 | 48 | 65 | 2 | 7 | - | 1 | 6 | - | - | 1 | - |
E5/1.5/135* | 75 | 48 | 65 | 1.5 | 7 | - | 1 | 6 | - | - | 1 | - |
*angle bracket folded at 135°
Wood/wood connection beam/beam type - assembly with 2 angle brackets
References | Product capacities - Timber to timber - Beam to beam - Full nailing | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Number of Fasteners | Characteristic capacities - Timber C24 - 2 angle brackets per connection [kN] | |||||||||
Joist | Flange B | R1.k | R2.k = R3.k | |||||||
Qty | Qty | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | |
E5/1.5 | 7 | 6 | 6.1 | 7.1 | 8.6 | 9.3 | 9.8 | 10.8 | 13 | 14 |
E5/1.5/11.22/11 | 7 | 6 | 6.1 | 7.1 | 8.6 | 9.3 | 9.8 | 10.8 | 13 | 14 |
E5/2 | 7 | 6 | 6.1 | 7.1 | 8.6 | 9.8 | 9.8 | 10.8 | 13 | 14 |
E4/2.5 | 8 | 6 | 5.5 | 6.3 | 7.2 | 7.6 | 7.6 | 8.3 | 10.1 | 10.7 |
E6/2 | 11 | 6 | 4.1 | 5 | 6.6 | 8.3 | 5.2 | 5.7 | 9 | 9.6 |
E6/2.5 | 11 | 6 | 5.5 | 6.3 | 7.2 | 7.6 | 9.4 | 10.3 | 12.5 | 13.3 |
E7/2.5 | 13 | 6 | 5.5 | 6.3 | 7.2 | 7.6 | 10 | 11 | 13.3 | 14.2 |
E8/2.5 | 13 | 6 | 5.5 | 6.3 | 7.2 | 7.6 | 10 | 11 | 13.3 | 14.2 |
E14/2 | 8 | 4 | 4.2 | 5.1 | 6.7 | 8.4 | 5.3 | 5.8 | 7.7 | 9.7 |
E17/2 | 15 | 4 | 4.9 | 5.6 | 6.7 | 7.4 | 8.2 | 9 | 10.9 | 11.6 |
E18/2.5 | 15 | 4 | 4.9 | 5.6 | 6.7 | 7.4 | 8.2 | 9 | 10.8 | 11.5 |
E19/3 | 15 | 4 | 4.9 | 5.6 | 6.7 | 7.4 | 8.2 | 9 | 10.7 | 11.4 |
E5/2C50 | 7 | 6 | 6.1 | 7.1 | 8.6 | 9.8 | 9.8 | 10.8 | 13 | 14 |
To obtain the resistance values for a single bracket, the values in the above table should be divided by two, provided that the supported beam is locked in rotation. Please consult our ETA-06/0106 if the beam is free to rotate.
Wood/wood connection post/beam type - assembly with 2 angle brackets
References | Product capacities - Timber to timber - Post to beam - Partial nailing | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Number of Fasteners | Characteristic capacities - Timber C24 - 2 angle brackets per connection [kN] | |||||||||
Joist | Flange B | R1.k | R2.k = R3.k | |||||||
Qty | Qty | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | |
E6/2 | 8 | 6 | 4.1 | 5 | 6.6 | 8.3 | 5.2 | 6.3 | 7.6 | 9.6 |
E6/2.5 | 8 | 6 | 4.1 | 5 | 6.6 | 8.3 | 5.3 | 6.3 | 9 | 9.6 |
E7/2.5 | 10 | 6 | 4.2 | 5 | 6.7 | 8.3 | 6.2 | 7.5 | 11.5 | 12.1 |
E8/2.5 | 10 | 6 | 4.2 | 5 | 6.7 | 8.3 | 6.2 | 7.5 | 11.5 | 12.1 |
E17/2 | 12 | 4 | 4.2 | 5.1 | 6.7 | 8.3 | 6.7 | 7.3 | 10.7 | 11.3 |
E18/2.5 | 12 | 4 | 4.2 | 5.1 | 6.7 | 8.3 | 6.9 | 7.6 | 11.1 | 11.9 |
E19/3 | 12 | 4 | 4.2 | 5.1 | 6.7 | 8.3 | 6.5 | 7.1 | 10.7 | 11.4 |
E5/2C50 | - | - | - | - | - | - | - | - | - | - |
To obtain the resistance values for a single bracket, the values in the above table should be divided by two, provided that the supported beam is locked in rotation. Please consult our ETA-06/0106 if the beam is free to rotate.
Wood/rigid substrate connection beam/rigid substrate type - assembly with 2 angle brackets
References | Product capacities - Timber beam to rigid support | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Fasteners | Characteristic capacities - Timber C24 - 2 angle brackets per connection [kN] | |||||||||||
Joist | Flange B | R1.k | R2.k = R3.k | |||||||||
Qty | Type | Qty | Type | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | |
E5/1.5 | 7 | CNA | 1 | Ø10 | 6.6 | 6.6 | 6.6 | 6.6 | - * | - * | - * | - * |
E5/1.5/11.22/11 | 7 | CNA | 1 | Ø10 | 6.6 | 6.6 | 6.6 | 6.6 | 5.8 | 6.7 | 8.6 | 9.9 |
E5/2 | 7 | CNA | 1 | Ø10 | 8.4 | 8.4 | 8.4 | 8.4 | - * | - * | - * | - * |
E4/2.5 | 8 | CNA | 1 | Ø10 | 12.6 | 12.6 | 12.6 | 12.6 | - * | - * | - * | - * |
E6/2 | 11 | CNA | 1 | Ø10 | 6.5 | 7.9 | 8.6 | 10.8 | - * | - * | - * | - * |
E6/2.5 | 11 | CNA | 1 | Ø10 | 12.6 | 12.6 | 12.6 | 12.6 | - * | - * | - * | - * |
E7/2.5 | 13 | CNA | 1 | Ø10 | 12.7 | 12.7 | 12.7 | 12.7 | - * | - * | - * | - * |
E8/2.5 | 13 | CNA | 1 | Ø10 | 12.7 | 12.7 | 12.7 | 12.7 | - * | - * | - * | - * |
E14/2 | 8 | CNA | 1 | Ø12 | 3.6 | 4.4 | 5 | 6.3 | 3.4 | 4.1 | 5.5 | 6.9 |
E17/2 | 15 | CNA | 1 | Ø12 | 15.2 | 15.2 | 15.2 | 15.2 | 5.8 | 6.6 | 8.3 | 9.4 |
E18/2.5 | 15 | CNA | 1 | Ø12 | 20.5 | 20.5 | 20.5 | 20.5 | 8.1 | 9.3 | 11.6 | 13.1 |
E19/3 | 15 | CNA | 1 | Ø12 | 28.1 | 28.1 | 28.1 | 28.1 | 8.1 | 9.2 | 11.6 | 13 |
E5/2C50 | 7 | CNA | 1 | Ø10 | 8.4 | 8.4 | 8.4 | 8.4 | - * | - * | - * | - * |
* No capacities are given as it is a slip connection due to oblong hole.
To obtain the resistance values for a single bracket, the values in the above table should be divided by two, provided that the supported beam is locked in rotation. Please consult our ETA-06/0106 if the beam is free to rotate.
Wood/rigid substrate connection post/rigid substrate type - assembly with 2 angle brackets
References | Product capacities - Timber post to rigid support | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Fasteners | Characteristic capacities - Timber C24 - 2 angle brackets per connection [kN] | |||||||||||
Joist | Flange B | R1.k | R2.k = R3.k | |||||||||
Qty | Type | Qty | Type | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | |
E6/2 | 8 | CNA | 1 | Ø10 | 3.3 | 4 | 5.3 | 6.6 | - * | - * | - * | - * |
E6/2.5 | 8 | CNA | 1 | Ø10 | 3.3 | 4 | 5.3 | 6.6 | - * | - * | - * | - * |
E7/2.5 | 10 | CNA | 1 | Ø10 | 3.3 | 4 | 5.3 | 6.6 | - * | - * | - * | - * |
E8/2.5 | 10 | CNA | 1 | Ø10 | 3.3 | 4 | 5.3 | 6.6 | - * | - * | - * | - * |
E17/2 | 12 | CNA | 1 | Ø12 | 10.2 | 12.4 | 12.6 | 15.8 | 3.4 | 3.7 | 5.3 | 5.6 |
E18/2.5 | 12 | CNA | 1 | Ø12 | 10 | 12.2 | 15.3 | 19.2 | 3.4 | 3.7 | 6.6 | 7 |
E19/3 | 12 | CNA | 1 | Ø12 | 10 | 12.2 | 15.3 | 19.2 | 5.9 | 6.5 | 10 | 10.7 |
E5/2C50 | - | - | - | - | - | - | - | - | - | - | - | - |
* No capacities are given as it is a slip connection due to oblong hole.
To obtain the resistance values for a single bracket, the values in the above table should be divided by two, provided that the supported beam is locked in rotation. Please consult our ETA-06/0106 if the beam is free to rotate.
Product characteristic capacities - Timber beam to timber beam - Ø10 connector screws - 2 angle brackets
References | Product capacities - Timber beam to timber beam - Ø10 connector screws - 2 angle brackets | ||||
---|---|---|---|---|---|
Fasteners | Characteristic capacities - Timber C24 - 2 angle brackets per connection [kN] | ||||
Flange A | Flange B | R1.k | |||
Qty | Type | Qty | Type | SSH10x40 | |
E5/1.5 | 1 | SSH | 1 | SSH | 3.1 |
E5/1.5/11.22/11 | 1 | SSH | 1 | SSH | 3.1 |
Product characteristic capacities - Timber beam to rigid support - Ø10 connector screws - 2 angle brackets
References | Product capacities - Timber beam to concrete - Ø10 connector screws - 2 angle brackets | ||||
---|---|---|---|---|---|
Fasteners | Characteristic capacities - Timber C24 - 2 angle brackets per connection [kN] | ||||
Flange A | Flange B | R1.k | |||
Qty | Type | Qty | Type | SSH10x40 | |
E5/1.5 | 1 | SSH | 1 | Ø10 | 5 |
E5/1.5/11.22/11 | 1 | SSH | 1 | Ø10 | 5 |
Installation
Installation
Fixing
On wood:
- CNA annular ring-shank nails dia. 4.0 x 35 or dia. 4.0 x 50 mm.
- CSA screws dia. 5.0 x 35 mm or CSA screws dia. 5.0 x 40 mm.
- Bolts.
- LAG screws.
On concrete:
Concrete substrate
- Mechanical anchor: WA M10-78/5 OR WA M12-104/5 pin.
- Chemical anchor: AT-HP resin + LMAS M10-120/25 or LMAS M12-150/35 threaded rod.
Hollow masonry substrate:
- Chemical anchor: AT-HP or POLY-GP resin + LMAS M12-150/35 threaded rod + SH M16-130 screen.
On steel:
- Bolts.
Installation
- Come with the joist,
- Add nails. It can be also screwed,
- If the header is made out of timber, the angle bracket can be attached to it with nails or screw,
- If the header is made out of concrete, the angle bracket must be attached with adapted anchors (using the installation data from the anchor)
Technical Notes
Informations
F1: tensile force in the central axis of the angle-bracket
Particular situation of a fastening with only one angle-bracket:
- If the overall structure prevents the rotation of the purlin or the post, the tensile strength is equal to half of the given value for two angle-brackets.
- Otherwise, the connection resistance depends on the « f » distance between the vertical contact surface and the point of load application.
F2 and F3: shear lateral force
Particular situation of a connection with only one angle-bracket:
- The resistance value to consider is equal to half of the one given for two angle-brackets.
F4 and F5: transversal force directed towards or opposite the angle-bracket
- The connection resistance depends on the « e » distance between the base of the angle-bracket and the point of load application.
- To consult corresponding loads, contact us.
Only F1, F2 and F3 forces for connections with 2 angle-brackets are present on this sheet.