Adjustable Post Base
The PPRC allows the structure to be adjusted after it has been built.
Adjust the off the ground height from 100 to 150mm even after the post has been installed.
Suitable for posts 100x100mm to 200x200mm
Product Details
Features
Material
- dichromate coated galvanised mild steel.
Benefits
- PPRC can be adjusted after the installation.
- Does not require machining.
Application
Suitable On
- Supporting member: solid wood, glued-laminated wood, concrete.
- Supported member: solid wood, composite lumber, glued-laminated wood.
Applications
- Awning posts.
- Pergola.
- Veranda.
Technical Data
Characteristic capacities- Timber to Concrete
References | Number of Fasteners | Characteristic capacities - Timber C24 [kN] | |||
---|---|---|---|---|---|
On post | On concrete | R1,k | |||
Qty | Type | Qty | Type | ||
PPRC | 4 | Ø10 | 4 | Ø10* | 51.1 / kmod^0.5 |
* Refer to the Simpson Strong-Tie anchor product range for suitable anchors. Typical anchor solutions are BOAXII, SET-XP, WA, AT-HP, depending on the concrete type, spacing and edge distances.
Characteristic Capacites - Timber to Concrete
References | Fasteners | Simplified characteristic capacities - Timber C24 [kN] | |||
---|---|---|---|---|---|
On post | On concrete | R1,k** | |||
Qty | Type | Qty | Type | ||
PPRC | 4 | Ø10 | 4 | Ø10* | 61 |
* Refer to the Simpson Strong-Tie anchor product range for suitable anchors. Typical anchor solutions are SET-XP and AT-HP, depending on the concrete type, spacing and edge distances.
**The published characteristic capacity is based on medium term load duration and service class 2 according to EC5 (EN 1995). For other load duration and service class, please refer to the ETA to get more accurate capacities.
Installation
Installation
Fixings
On wood post:
- LAG screws 10 x 80 mm.
- SSH screws Ø 10 x 80 mm
On concrete:
- Mechanical anchor: WA M10-78/5 pin.
- Chemical anchor: AT-HP resin + LMAS M10-120/25 threaded rod.
Installation
- Fix to the foundation with M10 anchors. fix the post using M10 coach screws.
- 130 x 130mm plate fixes to the ground.
- 100 x 100mm plate fasteners to the post.
- PPRC can be adjusted with a 30mm wrench after both plates are attached.
- not recommended when the top of post/column is not restrained (e.g. fence post).