Large reinforced angle brackets
Reinforced angle brackets are suitable for structural applications in framing and wood-frame houses.
Product Details
Features
Material
- Galvanized steel S250GD + Z275 according to NF EN 10346.
Benefits
- Extremely strong angle bracket!
- Suitable for anchoring as it can withstand both suction and pull in all directions
- I single angle bracket E20/3 each side of the assembly will result in an extremely strong ans secure construction
- 2 angle brackets can be used as an alternative to a joisthanger
Application
Suitable On
- Supporting member: solid wood, glued-laminated wood, concrete, steel, etc.
- Supported member: solid wood, composite lumber, glued-laminated wood, triangular trusses, profiles, etc.
When to Use
- Fastening of small trusses.
- Cladding plates, cladding uprights.
- Rafter anchors, cantilevers, headers, etc.
Technical Data
Product capacities - Timber beam to timber beam - Full nailing - 2 angles brackets
References | Product capacities - Timber to timber - Full nailing | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Number of Fasteners | Characteristic capacities - Timber C24 - 2 angle brackets per connection [kN] | |||||||||
Joist | Flange B | R1.k | R2.k = R3.k | |||||||
Qty | Qty | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | |
E20/3 | 24 | 16 | 7.34 | 8.95 | 11.77 | 14.71 | 19.89 | 21.86 | 26.61 | 28.31 |
The published characteristic capacity is based on short term load duration and service class 2 according to EC5 (EN 1995) – kmod = 0,9. For other load duration and service class, please refer to the ETA to get more accurate capacities.
To obtain the resistance values for a single bracket, the values in the above table should be divided by two, provided that the supported beam is locked in rotation. Please consult our ETA-06/0106 if the beam is free to rotate.
Product capacities - Timber beam to timber beam - Partial nailing - 2 angles brackets
References | Product capacities - Timber beam to timber beam - Partial nailing | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Number of Fasteners | Characteristic capacities - Timber C24 - 2 angle brackets per connection [kN] | |||||||||
Joist | Flange B | R1.k | R2.k = R3.k | |||||||
Qty | Qty | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | |
E20/3 | 12 | 9 | 5.56 | 6.78 | 8.78 | 10.97 | 15 | 16.48 | 20.22 | 21.51 |
The published characteristic capacity is based on short term load duration and service class 2 according to EC5 (EN 1995) – kmod = 0,9. For other load duration and service class, please refer to the ETA to get more accurate capacities.
To obtain the resistance values for a single bracket, the values in the above table should be divided by two, provided that the supported beam is locked in rotation. Please consult our ETA-06/0106 if the beam is free to rotate.
Product capacities - Timber post to timber beam - Partial nailing - 2 angles brackets
References | Product capacities - Timber post to timber beam - Partial nailing | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Number of Fasteners | Characteristic capacities - Timber C24 - 2 angle brackets per connection [kN] | |||||||||
Joist | Flange B | R1.k | R2.k = R3.k | |||||||
Qty | Qty | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | |
E20/3 | 13 | 8 | 5.56 | 6.78 | 8.78 | 10.97 | 11.77 | 12.93 | 15.91 | 16.92 |
The published characteristic capacity is based on short term load duration and service class 2 according to EC5 (EN 1995) – kmod = 0,9. For other load duration and service class, please refer to the ETA to get more accurate capacities”.
To obtain the resistance values for a single bracket, the values in the above table should be divided by two, provided that the supported beam is locked in rotation. Please consult our ETA-06/0106 if the beam is free to rotate.
Product capacities - Trimmer connection - Partial nailing - 2 angles brackets
References | Product capacities - Timber to timber - Trimmer connection | |||||
---|---|---|---|---|---|---|
Number of Fasteners | Characteristic capacities - Timber C24 - 2 angle brackets per connection [kN] | |||||
Joist | Flange B | R2.k = R3.k | ||||
Qty | Qty | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | |
E20/3 | 18 | 16 | 12.67 | 15.45 | 19.31 | 24.14 |
The published characteristic capacity is based on short term load duration and service class 2 according to EC5 (EN 1995) – kmod = 0,9. For other load duration and service class, please refer to the ETA to get more accurate capacities.
To obtain the resistance values for a single bracket, the values in the above table should be divided by two, provided that the supported beam is locked in rotation. Please consult our ETA-06/0106 if the beam is free to rotate.
Product capacities - Timber beam to rigid support - Full nailing - 2 angles brackets
References | Product capacities - Timber to Concrete - Full nailing | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Fasteners | Characteristic capacities - Timber C24 - 2 angle brackets per connection [kN] | |||||||||||
Joist | Flange B | R1.k | R2.k = R3.k | |||||||||
Qty | Type | Qty | Type | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | |
E20/3 | 24 | CNA | 4 | Ø10 | 53.7 | 65.5 | 71 | 88.8 | 39 | 42.9 | 44.7 | 47.5 |
The published characteristic capacity is based on short term load duration and service class 2 according to EC5 (EN 1995) – kmod = 0,9. For other load duration and service class, please refer to the ETA to get more accurate capacities.
To obtain the resistance values for a single bracket, the values in the above table should be divided by two, provided that the supported beam is locked in rotation. Please consult our ETA-06/0106 if the beam is free to rotate.
Product capacities - Timber beam to rigid support - Partial nailing - 2 angles brackets
References | Product capacities - Timber to Concrete - Partial nailing | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Fasteners | Characteristic capacities - Timber C24 - 2 angle brackets per connection [kN] | |||||||||||
Joist | Flange B | R1.k | R2.k = R3.k | |||||||||
Qty | Type | Qty | Type | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | |
E20/3 | 13 | CNA | 4 | Ø10 | 30.2 | 36.9 | 40 | 50 | 25.4 | 28 | 29.1 | 31 |
The published characteristic capacity is based on short term load duration and service class 2 according to EC5 (EN 1995) – kmod = 0,9. For other load duration and service class, please refer to the ETA to get more accurate capacities.
To obtain the resistance values for a single bracket, the values in the above table should be divided by two, provided that the supported beam is locked in rotation. Please consult our ETA-06/0106 if the beam is free to rotate.
Product capacities - CLT beam to CLT beam - Ø10 connector screws - 2 angles brackets
References | Product capacities - CLT beam to CLT beam - Ø10 connector screws - 2 angle brackets | |||||
---|---|---|---|---|---|---|
Fasteners | Characteristic capacities - Timber CLT - 2 angle brackets per connection [kN] | |||||
Flange A | Flange B | R1.k | R2.k = R3.k | |||
Qty | Type | Qty | Type | SSH10x80 | SSH10x80 | |
E20/3 | 5 | SSH | 4 | SSH | 29 | 26 |
Installation
Installation
Fixing
On wood:
- CNA annular ring-shank nails dia. 4.0 x 35 or dia. 4.0 x 50 mm.
- CSA screws dia. 5.0 x 35 mm or CSA screws dia. 5.0 x 40 mm.
- Bolts.
- LAG screws.
On concrete:
Concrete substrate
- Mechanical anchor: WA M10-78/5 OR WA M12-104/5 pin.
- Chemical anchor: AT-HP resin + LMAS M10-120/25 or LMAS M12-150/35 threaded rod.
Hollow masonry substrate:
- Chemical anchor: AT-HP or POLY-GP resin + LMAS M12-150/35 threaded rod + SH M16-130 screen.
On steel:
- Bolts.
Installation
• For home and garden
Technical Notes
Technical information
F1: tensile force in the central axis of the angle-bracket
Particular situation of a fastening with only one angle-bracket:
- If the overall structure prevents the rotation of the purlin or the post, the tensile strength is equal to half of the given value for two angle-brackets.
- Otherwise, the connection resistance depends on the « f » distance between the vertical contact surface and the point of load application.
F2 and F3: shear lateral force
Particular situation of a connection with only one angle-bracket:
- The resistance value to consider is equal to half of the one given for two angle-brackets.
F4 and F5: transversal force directed towards or opposite the angle-bracket
- The connection resistance depends on the « e » distance between the base of the angle-bracket and the point of load application.
- To consult corresponding loads, contact us.
Only F1, F2 and F3 forces for connections with 2 angle-brackets are present on this sheet.